Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
20999 | 3M CO ADMININISTRATIVE ELECTRONIC & |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFZL | EXPANDED INSIDE DIAMETER | 0.063 INCHES NOMINAL |
CQBC | MINIMUM TENSILE STRENGTH | 2200 POUNDS PER SQUARE INCH |
AFZN | RECOVERED WALL THICKNESS | 0.017 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | SHRINKABLE |
FLEX | FLEXIBILITY | FLEXIBLE |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND SOLVENT RESISTANT |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 50.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
MATL | MATERIAL | RUBBER, SYNTHETIC, MIL-R-46846, TYPE 5 |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 500.0 |
ABJH | TEMP RATING | -50.0 DEG CELSIUS AND 135.0 DEG CELSIUS |
AFZM | RECOVERED INSIDE DIAMETER | 0.031 INCHES NOMINAL |
HUES | COLOR | WHITE |
ZZZT | NONDEFINITIVE SPEC/STD DATA | 5 TYPE |